Organic fertilizer equipment is prone to wear or failure after too long use or improper use, and then introduce the common fault analysis and solutions of horizontal mixers
1, the drive shaft wear deformation; 2, bearing damage; 3. The bearing seat or reducer fixing bolt is loose
Treatment measures 1, repair or replace the drive shaft 2, replace the bearing; 3. Tighten the bolt again.
Reducer oil temperature is too high fault analysis 1, drive shaft wear deformation; 2, bearing damage; 3. Too much ash accumulates in the box, and the resistance increases.
Treatment measures 1, repair or replace the drive shaft; 2, replace the bearing; 3. Rinse in time.
Failure analysis of insufficient water content 1, water pressure is not enough 2, nozzle blockage
Treatment measures 1, increase the water pressure 2, clean or replace
Shaft end disk ash fault analysis 1, spindle wear 2, packing wear
Treatment measures 1, repair or replace 2, replace the filler.